Changchun New Industries Optoelectronics Technology Co., Ltd.
 
Lasers, Optics & Photonics

Products
Lasers
Spectrum Analyzers
Laser Application Systems
Laser Measurement Tools
Laser Marking
Fiber-Coupled Lasers & LEDs
Optics & Coatings
Laboratory Instruments
Components & Accessories
 
Spectrum Analysis
Fiber Optic Spectrometer
Raman Spectrometer
Fluorescence Spectrometer
LIBS
A/T Spectrum Detection System
CRDS Detection System
TRS Detection System
Probe
Laser Sources
Components & Accessories
 
Customer Service
TTL or Analog Modulation
Fiber Coupling
Coating Service
Laser Marking Service
Customized Products
 
Contact CNI
Tel: +86-431-85603799 / 89216078
Fax:    +86-431-89216068
E-mail:  sales@cnilaser.com
国内: 0431-87020257 / 89216068

 

 

Portable Raman Spectrometer

 
The portable Raman spectrometer RamanSys-405, RamanSys-532 and RamanSys-785,researched and developed by CNI, which apply to the field of food safety, environmental sciences and judicial identification etc. They have the advantages of portable, high resolution, high sensitivity and so on.

 

 

Portable Raman spectrometer

Features:

  • Spectrometer resolution
    RamanSys-405: <12cm-1
    RamanSys-488:12cm-1
    RamanSys-532: <12cm-1   
    RamanSys-633: <12cm-1 
    RamanSys-785: <5cm-1
    RamanSys-830: <7cm-1

  • Broad spectral range, Raman drift range
    RamanSys-405: 300-3000cm-1
    RamanSys-488: 450-3000cm-1
    RamanSys-532: 150-4500cm-1
    RamanSys-633: 110-3000cm-1
    RamanSys-785: 150-3648cm-1
    RamanSys-830: 200-2048cm-1

  • Customized wavelength range and resolution

  • Fit various applications

  • Compatible with software Raman Analysis 2.0

Applications:

  • Raman spectral analysis

  • Chemical or biological research

  • Environmental sciences

  • Diamond identification

  • Food safety testing

  • Judicial identification

  • Pharmaceutical and medical diagnosis

  • Geological exploration

  • Hazard detection

Basic Composition
 

Portable Raman Spectrometer

RamanSys-532 Raman spectrometer
405nm/ 488nm/ 532nm/ 633nm/ 785nm/ 830nm fiber coupled laser
Spectrometer: Raman Standard: Sunshine GE-Raman
RPB-405/ 488/532/633/785/830 Raman Probe

Man-machine interface

 
 
Specifications
 
                    Laser

Wavelength (nm)

405±0.5

488±0.5

532±0.5

633±0.5

785±0.3

830±5

Mode

Single

Single

Single

Single

Single

Multi-

Spectral line width (cm-1)

1.8

3.5/ 1.2

3.5/ 0.1

<0.7

<3.2

<28

Output power (mW)

1-500

1-150

1-1000

1-80

1-500

1-900

Power stability (pk-pk, 4 hours)

<1%,<3%,<5%

<1%,<3%,<5%

<1%,<3%,<5%

<1%,<3%,<5%

<1%,<3%,<5%

<1%,<3%,<5%

Parameter of fiber

100um@0.22NA

100um@0.22NA

100um@0.22NA

100um@0.22NA

100um@0.22NA

100um@0.22NA

Noise of amplitude(rms)

-

<1%

<0.5%

<1%

<0.5%,<1%

<1%

Operating mode

CW

CW

CW

CW

CW

CW

Warm-up time(minutes)

<5

<5

<10

<5

<5

<5

Operating temperature (℃)

10-35

10-35

15-35

10-35

10-40

10-35

Expected lifetime (hours)

10000

10000

10000

10000

10000

10000

Warranty

1 year

1 year

1 year

1 year

1 year

1 year

 
                    Spectrometer

Wavelength range

405-461nm
(405nm excitation)

488-572nm
(488nm excitation)

532-700nm
(532nm excitation)

633-781nm
(633nm excitation)

785-1100nm
(785nm excitation)

830-1000nm
(830nm excitation)

Optical resolution

8-12cm-1
(405nm excitation)

8-12cm-1
(488nm excitation)

8-12cm-1
(532nm excitation)

8-12cm-1
(633nm excitation)

5-8cm-1
(785nm excitation)

5-7cm-1
(830nm excitation)

Pixels

2048 pixels

Pixels size

14um*14um

Dimensions (mm)

149*109*50

Weight (g)

1000

Signal-to-noise ratio

1000:1

Integration time

17ms-10s

Power consumption

450mA@5VDC

Data transfer speed

Full scans into memory every 4 milliseconds with USB 2.0
Full scans into memory every 18 milliseconds with USB 1.1

Connector

30pin connector

 
                    Raman Probe

Excitation wavelength (nm)

405

488

532

633

785±

830

Probe focus length (mm)

7.5

Probe main material

Probe material is 2A12 after Blackening; Stainless steel detector tip

Fiber configuration

Two single fiber (100um excitation fiber, 200um optical fiber for collecting light); N.A.=0.22, PVC/metal sheath; 1m Length

 
                    Software

Optical spectrum analysis

Spectral Analysis / Raman Analysis 2.0

Operating system

Windows XP/ Win7/ Win10 (32bits or 64 bits)

 
 
Characteristic
  • Dimensions: RamanSys-405/ 785:340*295*152mm; RamanSys-532:418*330*173mm

  • Adjustable and stable 405/ 488/ 532/ 633/ 785/ 830nm laser source
  • Simple, fast measurement and easy operation
  • Function with matching library and searching, provided convenient self-built library function
  • Flexible and stable sampling, various forms in analyzing samples
  • External power supply (charging), with vehicle-mounted charger
  • Dustproof, waterproof, anti-vibration, Anti-glare interference in wild environment usage
Applications
 
Accessories
 

 

Addr: No.888 Jinhu Road High-tech Zone,Changchun 130103, P.R.China

 International Tel: +86-431-85603799  Domestic Tel:  0431-87020257  Fax:+86-431-89216068   
 

在线客服