Desktop Raman
Spectrometer |
|
CNI researched
and developed desktop Raman spectrometers:
RamanSys-405,
RamanSys-532 and
RamanSys-785, which are available for connecting Raman probe
externally, They are feature with easy operation, high
resolution, high sensitivity and so on, widely used for
teaching, scientific research, food safety, environmental
science, identification of jewelry and many other fields. |
|
|
Features:
-
Spectrometer resolution
T-RamanSys-405:<12cm-1
T-RamanSys-532: <12cm-1
T-RamanSys-785: <5cm-1
T-RamanSys-830: <7cm-1
-
Broad spectral
range, Raman drift range
T-RamanSys-405:300-4700cm-1
T-RamanSys-532: 200-4500cm-1 T-RamanSys-785: 175-4000cm-1
T-RamanSys-830: 300-2048cm-1
-
Customized wavelength
range and resolution
-
Fit various applications
-
Compatible with software Raman Analysis
2.0
|
Applications:
|
|
■
Basic
Composition |
系列型号 |
|
|
■
Specifications |
|
Laser |
Wavelength (nm) |
405±0.5 |
532±0.5 |
785±0.3 |
830±5 |
Mode |
Single |
Single |
Single |
Multi- |
Spectral line width
(cm-1) |
1.8 |
3.5/ 0.1 |
<3.2 |
<28 |
Output power (mW) |
1-500 |
1-1000 |
1-500 |
1-900 |
Power stability (pk-pk, 4 hours) |
<1%,<3%,<5% |
<1%,<3%,<5% |
<1%,<3%,<5% |
<1%,<3%,<5% |
Parameter of
fiber |
100um@0.22NA |
100um@0.22NA |
100um@0.22NA |
100um@0.22NA |
Noise of amplitude(rms) |
- |
<0.5% |
<0.5%,<1% |
<1% |
Operating mode |
CW |
CW |
CW |
CW |
Warm-up time (minutes) |
<5 |
<10 |
<5 |
<5 |
Operating temperature (℃) |
10-35 |
15-35 |
10-40 |
10-35 |
Expected lifetime (hours) |
10000 |
10000 |
10000 |
10000 |
Warranty |
1 year |
1 year |
1 year |
1 year |
|
|
Spectrometer |
Wavelength range |
405-500nm
(405nm
excitation) |
532-700nm
(532nm excitation) |
785-1100nm
(785nm
excitation) |
830-1000nm
(785nm
excitation) |
Optical resolution |
8-12cm-1
(405nm excitation) |
8-12cm-1
(532nm excitation) |
5-8cm-1
(785nm
excitation) |
5-7cm-1
(830nm
excitation) |
Pixels |
2048 pixels |
Pixels size |
14um*14um |
Dimensions (mm) |
149*109*50 |
Weight (g) |
1000 |
Signal-to-noise ratio |
1000:1 |
Integration time |
17ms-10s |
Power consumption |
450mA@5VDC |
Data transfer speed |
Full scans into memory every 4
milliseconds with USB 2.0
Full scans into memory every 18
milliseconds with USB 1.1 |
Inputs/outputs |
5 inputs and 5 outputs
ports |
Analog channels |
One 12 analog input one 12 analog
output |
Connector |
30pin connector |
|
|
Software |
Optical spectrum analysis |
Spectral Analysis / Raman Analysis
2.0 |
Operating system |
Windows XP/Win7 (32bits
or 64 bits) |
|
|
■
Characteristic |
|
-
Dimensions: 420x 272x 160 mm
-
With adjustable and stable
405/ 532/ 785/ 830nm excitation laser
source
-
Raman probes can be
connected externally
-
Simple, fast measurement and
easy operation
-
Function with matching
library and searching,
provided convenient
self-built library function
-
flexible and stable
sampling, various forms in
analyzing samples
-
external power supply
(charging), with
vehicle-mounted charger
-
dustproof, waterproof,
anti-vibration, Anti-glare
interference in wild
environment usage
|
■
Applications |
|
■
Accessories |
|
|
|