CNI’s self-developed and manufactured 349 nm continuous-wave
(CW) and actively Q-switched pulsed UV laser series covers both continuous
output and actively Q-switched pulsed models, with core advantages including
low noise, high stability, narrow spectral linewidth and excellent beam
quality.
Supporting air or water cooling, they enable stable 24/7
operation with internal and external modulation control, and are fully
compatible with OEM integration. These lasers are widely used in spectral
analysis, semiconductor inspection, biomedicine, advanced scientific
research and precision machining.
|
|
|
|
Features
RMS Noise <
0.5%
CW
Output
Power Up to 4 W
Power
Stability < 0.5%
Spectral Linewidth< 1 MHz
CW/ Pulsed
Power adjustable & software controlled
|
Applications
Semiconductor / Wafer / SiC
Inspection
Raman Spectroscopy
Confocal Microscopy &
Fluorescence
Flow Cytometry
Biomedicine / Bioengineering |

UV-FN-349

MPL-F-349 |
|
|
Specifications |
| |
|
349
nm
Single Longitudinal Mode UV CW Laser |
|
Model |
Output
Power
(mW) |
Spectral Linewidth
(MHz) |
Power Stability
(rms, 4 Hours±3℃) |
RMS Noise |
|
MSL-FN-349 |
1~10mW |
<1 |
<1% |
<1% |
UV-FN-349-X
Ultra-compact |
1~50mW |
<1 |
<0.5% |
<0.25% |
|
UV-FN-349-SLM |
50~100mW |
<1 |
<0.5% |
<0.25% |
|
MSL-R-349 |
100~400mW |
<5 |
<1% |
<0.5% |
|
| |
|
349
nm
Low Noise UV CW Laser |
|
Model |
Output
Power
(mW) |
Spectral Linewidth
(MHz) |
Power Stability
(rms, 4 Hours±3℃) |
RMS Noise |
|
UV-FN-349-LN |
1~50mW |
<0.003 |
<1% |
<1% |
|
UV-DP-349-LN
|
50~2000mW |
<0.003 |
<0.5% |
<1% |
|
|
|
|
349 nm
High Stability
UV
CW
Laser |
|
Model |
Output
Power
(mW) |
Spectral Linewidth
(nm) |
Power Stability
(rms, 4 Hours±3℃) |
Features |
|
UV-FN-349 |
1~150mW |
<0.2 |
<1% |
M²<1.5 |
|
UV-DP-349-A |
150~400mW |
<0.2 |
<1% |
Air Cooled |
|
UV-DP-349-B
|
400~4000mW |
<0.2 |
<0.5% |
M²<1.2 |
|
UV-FN-349-SM |
1~50mW |
<0.2 |
<1% |
SM Fiber |
|
|
|
|
349 nm Passively Q-switched UV Laser |
|
Model |
Single Pulse Energy |
Average power (mW) |
Repetition Rate |
Pulse
Width
(ns) |
|
MPL-F-349 |
0.1~10µJ |
1~30 |
1-3 kHz |
0.1-2.5 |
|
| |
|
349 nm Actively Q-switched UV Laser |
|
Model |
Single Pulse Energy |
Average power (mW) |
Repetition Rate |
Pulse
Width
(ns) |
|
AO-S-349 |
1~8μJ |
1~15 |
1 Hz-1 kHz |
6-10@<10 kHz |
|
AO-S-349-FL |
1~60μJ |
1~100 |
1 Hz-5kHz |
~5@<1
kHz |
|
AO-V-349 |
1~267μJ |
1~800 |
3-10 kHz |
~10@3kHz |
|
| |
|
|
Measurement
Data |
 |
 |
|
Central Wavelength:
348.869nm @
UV-DP-349-B |
Output Power:
3.17 W @ UV-DP-349-B |
|
Linewidth: 16.0 pm @ UV-DP-349-B |
Power Stability <0.5% @